ITAC Assessment: NC0072
ITAC logo
ITAC Assessment: NC0072
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1995
Principal Product Compressors
NAICS
n/a
SIC 3563: Air and Gas Compressors
Sales Range $50
M
to 100
M
# of Employees 300
Plant Area 170,000
ft2
Annual Production 80,000
pieces
Production Hrs. Annual 6,000
hrs
Location (State) North Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $636,323 13,443,728
kWh
Natural Gas $105,342 24,324
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $152,584 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Other Liquid (non-haz) Savings Solid Waste (non-haz) Savings Personnel Changes Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $702 $780 n/a $702
12,603
kWh
- - - -
02 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,164 $96 n/a $1,164
22,567
kWh
- - - -
03 2.4133: Use most efficient type of electric motors $2,034 $1,678 n/a $2,034
42,790
kWh
- - - -
04 2.2511: Insulate bare equipment $343 $270 n/a - $343
-
MMBtu
- - -
05 2.1233: Analyze flue gas for proper air/fuel ratio $1,426 $600 n/a - $1,426
-
MMBtu
- - -
06 2.7314: Reduce ventilation air $2,692 $2,700 n/a $355
4,689
kWh
$2,337
-
MMBtu
- - -
07 2.7232: Replace existing hvac unit with high efficiency model $93,047 $400,000 n/a $43,047
365,768
kWh
- - - $50,000
08 2.7142: Utilize higher efficiency lamps and/or ballasts $851 $434 n/a $851
16,706
kWh
- - - -
09 3.5143: Return spent solutions to the manufacturer $45,541 $10,000 n/a $(-22.0)
(-1,172)
kWh
- $45,563
-
gal
- -
10 3.5315: Lease / purchase baler; sell cardboard to recycler $4,784 - n/a - - - $4,784
-
lb
-
TOTAL RECOMMENDED $152,584 $416,558 $48,131
463,951
kWh
$4,106
-
MMBtu
$45,563
-
gal
$4,784
-
lb
$50,000
TOTAL IMPLEMENTED - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Other Liquid (non-haz) Savings Solid Waste (non-haz) Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs