| Assessment Year | 2025 |
|---|---|
| Principal Product | Analytical Laboratory Instruments |
| NAICS | 334516: Analytical Laboratory Instrument Manufacturing |
| SIC | 3826: Laboratory Analytical Instruments |
| Sales Range | $10 M to 50M |
| # of Employees | 65 |
| Plant Area |
20,622
ft2
|
| Annual Production | 25,000
units
|
| Production Hrs. Annual | 2,772
hrs
|
| Location (State) | Nevada |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $47,939 | 516,298 |
kWh
|
$0.093 |
| Electricity Demand | $17,080 | 2,030 |
kW-mo/yr
|
$8.41 |
| Electricity Fees | $5,389 | - |
|
- |
| Natural Gas | $3,385 | 183 |
MMBtu
|
$18.51 |
| Other Energy | $493 | 1 |
MMBtu
|
$493.00 |
| TOTAL YEARLY COSTS | $74,286 | |||
| RECOMMENDED SAVINGS* | $85,292 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.9114: Use solar heat to make electricty | $35,454 | $296,882 |
$33,132
356,640
kWh
|
$2,322
-
kW-mo/yr
|
- | - | - | - | |
| 02 | 2.8114: Change rate schedules or other changes in utility service | $35,049 | $583 | - | - | $35,049 | - | - | - | |
| 03 | 2.8114: Change rate schedules or other changes in utility service | $6,087 | $583 | - | - | $2,146 | - | $3,941 | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,605 | $9,885 |
$2,779
29,912
kWh
|
$1,103
-
kW-mo/yr
|
- | - | - | $723 | |
| 05 | 2.7226: Use computer programs to optimize hvac performance | $2,499 | $3,310 |
$1,679
18,070
kWh
|
$726
-
kW-mo/yr
|
- |
$94
-
MMBtu
|
- | - | |
| 06 | 2.7144: Install spectral reflectors / delamp | $888 | $389 |
$346
3,725
kWh
|
$135
-
kW-mo/yr
|
- | - | - | $407 | |
| 07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $710 | $225 |
$559
6,016
kWh
|
$151
-
kW-mo/yr
|
- | - | - | - | |
| TOTAL RECOMMENDED | $85,292 | $311,857 |
$38,495
414,363
kWh
|
$4,437
-
kW-mo/yr
|
$37,195 |
$94
-
MMBtu
|
$3,941 | $1,130 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs