Assessment Year | 1995 |
---|---|
Principal Product | Contract Manufacturing |
NAICS |
n/a
|
SIC | 3490: |
Sales Range | $10 M to 50M |
# of Employees | 94 |
Plant Area |
42,000
ft2
|
Annual Production | 3,000,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $119,860 | 1,664,420 |
kWh
|
$0.072 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $15,446 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,358 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,358 | $360 |
$1,358
19,930
kWh
|
- | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,703 | $1,348 |
$1,703
30,188
kWh
|
- | |
03 | 2.4239: Eliminate or reduce compressed air usage | $634 | $1,600 |
$634
4,689
kWh
|
- | |
04 | 2.7241: Install outside air damper / economizer on hvac unit | $5,380 | $9,000 |
$5,380
99,648
kWh
|
- | |
05 | 2.7111: Reduce illumination to minimum necessary levels | $2,371 | $3,525 |
$2,371
34,877
kWh
|
- | |
06 | 3.5146: Utilize a central coolant system for cleaning and reuse of metal working fluid | $4,000 | $10,000 | - |
$4,000
-
lb
|
|
TOTAL RECOMMENDED | $15,446 | $25,833 |
$11,446
189,332
kWh
|
$4,000
-
lb
|
||
TOTAL IMPLEMENTED | $1,358 | $360 |
$1,358
19,930
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs