| Assessment Year | 1995 |
|---|---|
| Principal Product | Tempered Glass Products |
| NAICS |
n/a
|
| SIC | 3231: Glass Products, Made of Purchased Glass |
| Sales Range | $5 M to 10M |
| # of Employees | 70 |
| Plant Area |
100,550
ft2
|
| Annual Production | 1,400
thousand feet
|
| Production Hrs. Annual | 4,000
hrs
|
| Location (State) | Virginia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $160,856 | 2,581,477 |
kWh
|
$0.062 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $23,916 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $837 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Solid Waste (non-haz) Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $664 | $330 |
$664
10,844
kWh
|
- | |
| 02 | 2.4133: Use most efficient type of electric motors | $1,446 | $2,150 |
$1,446
23,447
kWh
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $122 | $560 |
$122
2,052
kWh
|
- | |
| 04 | 2.4131: Size electric motors for peak operating efficiency | $20,175 | $5,000 |
$20,175
325,615
kWh
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $173 | $274 |
$173
2,931
kWh
|
- | |
| 06 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $1,336 | - | - |
$1,336
-
lb
|
|
| TOTAL RECOMMENDED | $23,916 | $8,314 |
$22,580
364,889
kWh
|
$1,336
-
lb
|
||
| TOTAL IMPLEMENTED | $837 | $604 |
$837
13,775
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Solid Waste (non-haz) Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs