ITAC Assessment: NC0058
ITAC logo
ITAC Assessment: NC0058
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1995
Principal Product Blow Molded Plastics
NAICS
n/a
SIC 3085: Plastics Bottles
Sales Range $5
M
to 10
M
# of Employees 108
Plant Area 92,000
ft2
Annual Production 30,000,000
pieces
Production Hrs. Annual 8,760
hrs
Location (State) North Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $729,026 17,055,686
kWh
Natural Gas $26,073 4,904
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $92,552 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $44,346

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $149 $292 $149
3,224
kWh
-
02 2.4133: Use most efficient type of electric motors $16,902 $30,410 $16,902
379,836
kWh
-
03 2.2614: Use cooling tower or economizer to replace chiller cooling $3,940 $10,000 $3,940
123,681
kWh
-
04 2.3113: Make ice during off peak hours for cooling $19,158 $80,000 $19,158
-
kWh
-
05 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $1,618 $2,500 $1,618
36,342
kWh
-
06 2.7228: Avoid introducing hot, humid, or dirty air into hvac system $20,246 $4,000 $246
5,275
kWh
$20,000
-
MMBtu
07 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $11,975 $240 $11,975
269,050
kWh
-
08 2.3131: Reschedule plant operations or reduce load to avoid peaks $13,702 - $13,702
-
kWh
-
09 2.2511: Insulate bare equipment $4,862 $1,500 $4,862
109,320
kWh
-
TOTAL RECOMMENDED $92,552 $128,942 $72,552
926,728
kWh
$20,000
-
MMBtu
TOTAL IMPLEMENTED $44,346 $33,442 $44,346
688,452
kWh
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings