Assessment Year | 1995 |
---|---|
Principal Product | Acrylic Yarn |
NAICS |
n/a
|
SIC | 2298: Cordage and Twine |
Sales Range | $10 M to 50M |
# of Employees | 55 |
Plant Area |
105,600
ft2
|
Annual Production | 9,000,000
lb
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $214,257 | 1,594,373 |
kWh
|
$0.13 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $15,530 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,530 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7228: Avoid introducing hot, humid, or dirty air into hvac system | $3,963 | $1,500 |
$3,963
82,649
kWh
|
|
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,092 | $360 |
$2,092
30,481
kWh
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,362 | $11,760 |
$3,362
70,047
kWh
|
|
04 | 2.7111: Reduce illumination to minimum necessary levels | $3,675 | $475 |
$3,675
76,495
kWh
|
|
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,438 | $5,749 |
$2,438
68,875
kWh
|
|
TOTAL RECOMMENDED | $15,530 | $19,844 |
$15,530
328,547
kWh
|
||
TOTAL IMPLEMENTED | $4,530 | $6,109 |
$4,530
99,356
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs