Assessment Year | 1995 |
---|---|
Principal Product | Woven Narrow Fabrics |
NAICS |
n/a
|
SIC | 2241: Narrow Fabric and Other Smallware Mills: Cotton, Wool, Silk, and Manmade Fiber |
Sales Range | $1 M to 5M |
# of Employees | 37 |
Plant Area |
36,500
ft2
|
Annual Production | 2,400
thousand feet
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | South Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $42,198 | 631,008 |
kWh
|
$0.067 |
Fuel Oil #2 | $11,550 | 2,940 |
MMBtu
|
$3.93 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,751 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,364 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Fuel Oil #1 Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,554 | $476 |
$1,554
23,154
kWh
|
- | |
02 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $161 | $150 |
$161
2,638
kWh
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $833 | $2,100 |
$833
4,396
kWh
|
- | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $495 | $150 |
$495
7,327
kWh
|
- | |
05 | 2.4133: Use most efficient type of electric motors | $3,991 | $3,790 |
$3,991
59,496
kWh
|
- | |
06 | 2.2511: Insulate bare equipment | $1,717 | $248 | - |
$1,717
-
MMBtu
|
|
TOTAL RECOMMENDED | $8,751 | $6,914 |
$7,034
97,011
kWh
|
$1,717
-
MMBtu
|
||
TOTAL IMPLEMENTED | $6,364 | $4,338 |
$4,647
69,461
kWh
|
$1,717
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Fuel Oil #1 Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs