Assessment Year | 1995 |
---|---|
Principal Product | Dyed and Finished Knitted Cloth |
NAICS |
n/a
|
SIC | 2269: Finishers of Textiles, Not elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 450 |
Plant Area |
249,000
ft2
|
Annual Production | 12,500,000
lb
|
Production Hrs. Annual | 7,200
hrs
|
Location (State) | South Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $994,856 | 17,272,568 |
kWh
|
$0.058 |
Natural Gas | $375,347 | 123,503 |
MMBtu
|
$3.04 |
Wood | $241,352 | 189,108 |
MMBtu
|
$1.28 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $68,813 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $11,606 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Wood Savings | Solid Waste (non-haz) Savings | Solid Waste (haz) Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $2,276 | $570 |
$2,276
39,859
kWh
|
- | - | - | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,978 | $420 |
$1,978
34,584
kWh
|
- | - | - | - | |
03 | 2.6212: Turn off equipment during breaks, reduce operating time | $6,450 | $12,000 |
$6,450
113,130
kWh
|
- | - | - | - | |
04 | 2.4133: Use most efficient type of electric motors | $6,438 | $4,430 |
$6,438
112,837
kWh
|
- | - | - | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,206 | $1,960 |
$3,206
48,652
kWh
|
- | - | - | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $14,236 | $3,200 |
$14,236
268,464
kWh
|
- | - | - | - | |
07 | 3.6192: Use a less expensive method of waste removal | $3,190 | - | - | - | - |
$3,190
-
lb
|
- | |
08 | 3.6192: Use a less expensive method of waste removal | $24,714 | $18,000 | - | - |
$3,914
-
MMBtu
|
- |
$20,800
-
lb
|
|
09 | 2.1233: Analyze flue gas for proper air/fuel ratio | $6,325 | $3,800 | - |
$6,325
-
MMBtu
|
- | - | - | |
TOTAL RECOMMENDED | $68,813 | $44,380 |
$34,584
617,526
kWh
|
$6,325
-
MMBtu
|
$3,914
-
MMBtu
|
$3,190
-
lb
|
$20,800
-
lb
|
||
TOTAL IMPLEMENTED | $11,606 | $4,850 |
$8,416
147,421
kWh
|
- | - |
$3,190
-
lb
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Wood Savings | Solid Waste (non-haz) Savings | Solid Waste (haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs