Assessment Year 1995
Principal Product Electronic Components
NAICS
n/a
SIC 3621: Motors and Generators
Sales Range $10
M
to 50
M
# of Employees 190
Plant Area 106,000
ft2
Annual Production 5,000
pieces
Production Hrs. Annual 3,000
hrs
Location (State) North Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $186,219 3,143,904
kWh
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $48,071 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $13,382

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,182 $1,290 $3,182
53,927
kWh
-
02 2.7233: Use properly designed and sized hvac equipment $13,275 $180,000 $13,275
224,795
kWh
-
03 2.2437: Recover waste heat from equipment $1,443 $8,000 $1,443
24,619
kWh
-
04 2.7142: Utilize higher efficiency lamps and/or ballasts $1,293 $432 $1,293
21,981
kWh
-
05 2.7135: Install occupancy sensors $1,245 $3,600 $1,245
21,102
kWh
-
06 2.6221: Use most efficient equipment at it's maximum capacity and less efficient equipment only when necessary $4,915 $2,000 $4,915
83,236
kWh
-
07 2.7131: Add area lighting switches $478 $1,200 $478
8,206
kWh
-
08 2.7421: Reduce glazed areas in buildings $5,285 $1,400 $5,285
86,753
kWh
-
09 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $6,233 $4,000 $6,233
105,803
kWh
-
10 2.7235: Install fossil fuel make-up air unit $10,722 $2,115 $16,793
284,584
kWh
$(-6,071.0)
-
MMBtu
TOTAL RECOMMENDED $48,071 $204,037 $54,142
915,006
kWh
$(-6,071.0)
-
MMBtu
TOTAL IMPLEMENTED $13,382 $4,690 $13,382
223,916
kWh
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs