Assessment Year | 1995 |
---|---|
Principal Product | injection molded auto parts |
NAICS |
n/a
|
SIC | 3080: |
Sales Range | $10 M to 50M |
# of Employees | 205 |
Plant Area |
27,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $202,715 | 4,195,193 |
kWh
|
$0.048 |
Natural Gas | $16,311 | 2,800 |
MMBtu
|
$5.83 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $24,000 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,727 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,390 | $60 |
$2,390
55,686
kWh
|
|
02 | 2.4239: Eliminate or reduce compressed air usage | $2,105 | $320 |
$2,105
48,945
kWh
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,787 | $3,000 |
$2,787
64,771
kWh
|
|
04 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $3,881 | $1,500 |
$3,881
90,270
kWh
|
|
05 | 2.2622: Replace existing chiller with high efficiency model | $4,139 | $3,000 |
$4,139
140,680
kWh
|
|
06 | 2.4133: Use most efficient type of electric motors | $3,550 | $4,020 |
$3,550
82,649
kWh
|
|
07 | 2.2511: Insulate bare equipment | $5,148 | $906 |
$5,148
119,871
kWh
|
|
TOTAL RECOMMENDED | $24,000 | $12,806 |
$24,000
602,872
kWh
|
||
TOTAL IMPLEMENTED | $8,727 | $7,080 |
$8,727
203,106
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs