| Assessment Year | 1995 |
|---|---|
| Principal Product | injection molded auto parts |
| NAICS |
n/a
|
| SIC | 3080: |
| Sales Range | $10 M to 50M |
| # of Employees | 205 |
| Plant Area |
27,000
ft2
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | North Carolina |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $202,715 | 4,195,193 |
kWh
|
$0.048 |
| Natural Gas | $16,311 | 2,800 |
MMBtu
|
$5.83 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $24,000 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $8,727 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,390 | $60 |
$2,390
55,686
kWh
|
|
| 02 | 2.4239: Eliminate or reduce compressed air usage | $2,105 | $320 |
$2,105
48,945
kWh
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,787 | $3,000 |
$2,787
64,771
kWh
|
|
| 04 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $3,881 | $1,500 |
$3,881
90,270
kWh
|
|
| 05 | 2.2622: Replace existing chiller with high efficiency model | $4,139 | $3,000 |
$4,139
140,680
kWh
|
|
| 06 | 2.4133: Use most efficient type of electric motors | $3,550 | $4,020 |
$3,550
82,649
kWh
|
|
| 07 | 2.2511: Insulate bare equipment | $5,148 | $906 |
$5,148
119,871
kWh
|
|
| TOTAL RECOMMENDED | $24,000 | $12,806 |
$24,000
602,872
kWh
|
||
| TOTAL IMPLEMENTED | $8,727 | $7,080 |
$8,727
203,106
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs