Assessment Year | 1994 |
---|---|
Principal Product | Nonmetallic strapping |
NAICS |
n/a
|
SIC | 3081: Unsupported Plastics Film and Sheet |
Sales Range | $10 M to 50M |
# of Employees | 83 |
Plant Area |
90,000
ft2
|
Annual Production | 10,000,000
lb
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $348,821 | 7,874,854 |
kWh
|
$0.044 |
Natural Gas | $14,270 | 2,637 |
MMBtu
|
$5.41 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $34,522 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $14,991 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $8,164 | - |
$8,164
-
kWh
|
|
02 | 3.1161: Eliminate/reduce an operation | $447 | $500 |
$447
12,896
kWh
|
|
03 | 3.1161: Eliminate/reduce an operation | $10,452 | $500 |
$10,452
190,797
kWh
|
|
04 | 2.2612: Use cooling tower water instead of refrigeration | $5,719 | $8,750 |
$5,719
167,937
kWh
|
|
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,913 | $1,332 |
$2,913
66,237
kWh
|
|
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,827 | $390 |
$6,827
155,334
kWh
|
|
TOTAL RECOMMENDED | $34,522 | $11,472 |
$34,522
593,201
kWh
|
||
TOTAL IMPLEMENTED | $14,991 | $390 |
$14,991
155,334
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs