| Assessment Year | 1994 |
|---|---|
| Principal Product | APPLICATION OF PROTECTIVE POWDER COATINGS |
| NAICS |
n/a
|
| SIC | 2652: Setup Paperboard Boxes |
| Sales Range | $5 M to 10M |
| # of Employees | 28 |
| Plant Area |
40,000
ft2
|
| Annual Production | 17,500,000
lb
|
| Production Hrs. Annual | 2,000
hrs
|
| Location (State) | North Carolina |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $64,475 | 987,984 |
kWh
|
$0.065 |
| Natural Gas | $118,703 | 26,220 |
MMBtu
|
$4.53 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $24,916 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $7,556 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $410 | $302 |
$410
7,327
kWh
|
- | |
| 02 | 2.4133: Use most efficient type of electric motors | $1,282 | $3,800 |
$1,282
20,809
kWh
|
- | |
| 03 | 2.2424: Use heat in flue gases to preheat products or materials | $17,360 | $2,355 | - |
$17,360
-
MMBtu
|
|
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $580 | $55 |
$580
9,379
kWh
|
- | |
| 05 | 2.2511: Insulate bare equipment | $4,029 | $338 | - |
$4,029
-
MMBtu
|
|
| 06 | 2.4324: Replace hydraulic / pneumatic equipment with electric equipment | $1,255 | $4,012 |
$1,255
20,223
kWh
|
- | |
| TOTAL RECOMMENDED | $24,916 | $10,862 |
$3,527
57,738
kWh
|
$21,389
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $7,556 | $8,507 |
$3,527
57,738
kWh
|
$4,029
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs