Assessment Year | 2003 |
---|---|
Principal Product | woven cloth |
NAICS | 313210: Broadwoven Fabric Mills |
SIC | 2211: Broadwoven Fabric Mills, Cotton |
Sales Range | n/a |
# of Employees | 600 |
Plant Area |
950,000
ft2
|
Annual Production | 150,000,000
thousand feet
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $3,088,689 | 65,370,000 |
kWh
|
$0.047 |
Natural Gas | $189,205 | 38,872 |
MMBtu
|
$4.87 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $103,792 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $20,561 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Water Consumption Savings |
---|---|---|---|---|---|---|---|
01 | 2.1231: Establish burner maintenance schedule for boilers | $2,362 | $100 | - |
$2,362
-
MMBtu
|
- | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,500 | $1,250 |
$2,500
17,252
kWh
|
- | - | |
03 | 2.7124: Make a practice of turning off lights when not needed | $15,699 | $2,088 |
$15,699
234,067
kWh
|
- | - | |
04 | 2.2511: Insulate bare equipment | $2,317 | $298 | - |
$2,317
-
MMBtu
|
- | |
05 | 2.2211: Use optimum temperature | $9,365 | $5,650 | - |
$9,365
-
MMBtu
|
- | |
06 | 2.2449: Recover heat from exhausted steam, hot air or hot water | $16,712 | $6,500 | - |
$16,712
-
MMBtu
|
- | |
07 | 2.2511: Insulate bare equipment | $2,095 | $3,863 | - |
$2,095
-
MMBtu
|
- | |
08 | 2.2121: Increase amount of condensate returned | $25,099 | $11,100 | - |
$17,419
-
MMBtu
|
$7,680
-
Tgal
|
|
09 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $5,680 | $3,286 |
$5,680
172,474
kWh
|
- | - | |
10 | 2.4133: Use most efficient type of electric motors | $21,963 | $54,960 | n/a |
$21,963
753,818
kWh
|
- | - |
TOTAL RECOMMENDED | $103,792 | $89,095 |
$45,842
1,177,611
kWh
|
$50,270
-
MMBtu
|
$7,680
-
Tgal
|
||
TOTAL IMPLEMENTED | $20,561 | $3,438 |
$18,199
251,319
kWh
|
$2,362
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Water Consumption Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs