| Assessment Year | 1994 |
|---|---|
| Principal Product | WOOD CHAIRS AND TABLES |
| NAICS |
n/a
|
| SIC | 2511: Wood Household Furniture, Except Upholstered |
| Sales Range | $10 M to 50M |
| # of Employees | 683 |
| Plant Area |
544,000
ft2
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 2,500
hrs
|
| Location (State) | North Carolina |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $622,330 | 11,620,164 |
kWh
|
$0.054 |
| Natural Gas | $7,517 | 693 |
MMBtu
|
$10.85 |
| Coal | $147,117 | 86,265 |
MMBtu
|
$1.71 |
| Other Energy | $36,266 | 9,588 |
MMBtu
|
$3.78 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $234,234 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,831 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Coal Savings | Wood Savings | Other Energy Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.1222: Install turbulators | $68,797 | $3,000 | - |
$68,797
-
MMBtu
|
- | - | |
| 02 | 2.2414: Use waste heat from hot flue gases to preheat | $11,812 | $15,750 | - |
$11,812
-
MMBtu
|
- | - | |
| 03 | 2.3412: Use waste heat to produce steam to drive a steam turbine-generator | $5,634 | $38,500 |
$7,338
183,470
kWh
|
$(-1,704.0)
-
MMBtu
|
- | - | |
| 04 | 2.7313: Recycle air for heating, ventilation and air conditioning | $42,728 | $34,300 | - | - | - |
$42,728
-
MMBtu
|
|
| 05 | 2.2515: Use optimum thickness insulation | $61,266 | $133,293 | - | - | - |
$61,266
-
MMBtu
|
|
| 06 | 2.4221: Install compressor air intakes in coolest locations | $1,603 | $1,000 |
$1,603
29,601
kWh
|
- | - | - | |
| 07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,831 | $960 |
$1,831
33,998
kWh
|
- | - | - | |
| 08 | 2.1331: Burn a less expensive grade of fuel | $40,563 | $118,090 | - |
$147,117
-
MMBtu
|
$(-106,554.0)
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $234,234 | $344,893 |
$10,772
247,069
kWh
|
$226,022
-
MMBtu
|
$(-106,554.0)
-
MMBtu
|
$103,994
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $1,831 | $960 |
$1,831
33,998
kWh
|
- | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Coal Savings | Wood Savings | Other Energy Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs