Assessment Year | 1993 |
---|---|
Principal Product | Steel Buildings |
NAICS |
n/a
|
SIC | 3448: Prefabricated Metal Buildings and Components |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
194,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 3,800
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $420,995 | 5,455,158 |
kWh
|
$0.077 |
Natural Gas | $71,649 | 17,709 |
MMBtu
|
$4.05 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $37,423 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,568 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Other Energy Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,514 | $1,222 |
$6,514
95,838
kWh
|
- | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,054 | $690 |
$1,054
15,533
kWh
|
- | - | |
03 | 3.4115: Recover and reuse cooling water | $834 | $500 | - | - |
$834
-
MMBtu
|
|
04 | 2.2437: Recover waste heat from equipment | $26,384 | $1,500 | - |
$26,384
-
MMBtu
|
- | |
05 | 2.4131: Size electric motors for peak operating efficiency | $1,143 | $1,100 |
$1,143
16,706
kWh
|
- | - | |
06 | 2.7241: Install outside air damper / economizer on hvac unit | $1,494 | $4,500 |
$1,494
21,981
kWh
|
- | - | |
TOTAL RECOMMENDED | $37,423 | $9,512 |
$10,205
150,058
kWh
|
$26,384
-
MMBtu
|
$834
-
MMBtu
|
||
TOTAL IMPLEMENTED | $7,568 | $1,912 |
$7,568
111,371
kWh
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Other Energy Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs