Assessment Year | 2025 |
---|---|
Principal Product | grocery retail store |
NAICS | 445110: Supermarkets and Other Grocery (except Convenience) Stores |
SIC | 5411: Grocery Stores |
Sales Range | $10 M to 50M |
# of Employees | 20 |
Plant Area |
60,000
ft2
|
Annual Production | 1
pieces
|
Production Hrs. Annual | 5,400
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $90,002 | 1,244,900 |
kWh
|
$0.072 | |
Electricity Demand | $40,952 | 2,352 |
kW-mo/yr
|
$17.41 | |
Natural Gas | $7,627 | 681 |
MMBtu
|
$11.20 | |
Waste Disposal Costs | |||||
Water Usage | $9,454 | 253 |
Tgal
|
$37.39 | |
TOTAL YEARLY COSTS | $148,035 | ||||
RECOMMENDED SAVINGS* | $36,584 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $26,097 | $95,000 |
$20,004
277,838
kWh
|
$6,093
-
kW-mo/yr
|
|
02 | 2.7261: Install timers and/or thermostats | $3,592 | $1,550 |
$3,592
49,888
kWh
|
- | |
03 | 2.2531: Re-size charging openings or add movable cover or door | $1,463 | $2,550 |
$1,463
20,323
kWh
|
- | |
04 | 2.3113: Make ice during off peak hours for cooling | $5,432 | $11,250 |
$2,119
29,433
kWh
|
$3,313
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $36,584 | $110,350 |
$27,178
377,482
kWh
|
$9,406
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs