| Assessment Year | 2026 |
|---|---|
| Principal Product | Pharmaceutical formulation |
| NAICS | 325412: Pharmaceutical Preparation Manufacturing |
| SIC | 2834: Pharmaceutical Preparations |
| Sales Range | $50 M to 100M |
| # of Employees | 160 |
| Plant Area |
23,510
ft2
|
| Annual Production | 10,000,000
pieces
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | Missouri |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $595,216 | 6,841,563 |
kWh
|
$0.087 | |
| Electricity Demand | $52,213 | 11,948 |
kW-mo/yr
|
$4.37 | |
| Natural Gas | $166,382 | 20,730 |
MMBtu
|
$8.03 | |
| Waste Disposal Costs | |||||
| Water Usage | $75,971 | 21,120 |
Tgal
|
$3.60 | |
| TOTAL YEARLY COSTS | $889,782 | ||||
| RECOMMENDED SAVINGS* | $71,134 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $5,888 | $360 |
$5,508
63,312
kWh
|
$380
-
kW-mo/yr
|
- | |
| 02 | 2.2622: Replace existing chiller with high efficiency model | $18,343 | $120,000 |
$16,639
191,251
kWh
|
$1,704
-
kW-mo/yr
|
- | |
| 03 | 2.2622: Replace existing chiller with high efficiency model | $16,508 | $90,093 |
$14,511
166,799
kWh
|
$1,997
-
kW-mo/yr
|
- | |
| 04 | 2.2625: Chill water to the highest temperature possible | $9,886 | $16,248 |
$8,690
99,896
kWh
|
$1,196
-
kW-mo/yr
|
- | |
| 05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $4,116 | $2,000 | - | - |
$4,116
-
MMBtu
|
|
| 06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $7,569 | $19,800 |
$7,569
86,996
kWh
|
- | - | |
| 07 | 2.7135: Install occupancy sensors | $82 | $425 |
$82
936
kWh
|
- | - | |
| 08 | 2.2414: Use waste heat from hot flue gases to preheat | $8,742 | $70,000 | - | - |
$8,742
-
MMBtu
|
|
| TOTAL RECOMMENDED | $71,134 | $318,926 |
$52,999
609,190
kWh
|
$5,277
-
kW-mo/yr
|
$12,858
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs