ITAC Assessment: MZ0391
ITAC logo
ITAC Assessment: MZ0391
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2026
Principal Product lubrication equipment
NAICS 332999: All Other Miscellaneous Fabricated Metal Product Manufacturing
SIC 3499: Fabricated Metal Products, Not Elsewhere Classified
Sales Range $50
M
to 100
M
# of Employees 210
Plant Area 423,000
ft2
Annual Production 431,000
pieces
Production Hrs. Annual 4,480
hrs
Location (State) Missouri

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $506,941 6,601,193
kWh
Electricity Demand $51,391 13,893
kW-mo/yr
Electricity Fees $51,391 -
Natural Gas $54,200 9,806
MMBtu
TOTAL YEARLY COSTS $663,923
RECOMMENDED SAVINGS* $202,858 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Primary Raw Material Savings One-time Revenue or Avoided Cost Savings By-product Production Savings
01 2.2314: Replace heat treating oven with more efficient unit $52,407 $219,759 - - $5,687
-
MMBtu
$(-17,280.0) $10,000 $54,000
02 2.4231: Reduce the pressure of compressed air to the minimum required $2,041 $720 $1,808
23,481
kWh
$233
-
kW-mo/yr
- - - -
03 2.7221: Lower temperature during the winter season and vice-versa $4,207 - $1,160
15,069
kWh
- $3,047
-
MMBtu
- - -
04 2.4133: Use most efficient type of electric motors $20,145 $98,000 $20,145
261,632
kWh
- - - - -
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,007 - $1,007
13,081
kWh
- - - - -
06 2.9114: Use solar heat to make electricty $112,649 $1,062,750 $112,649
1,462,976
kWh
- - - - -
07 2.7491: Insulate glazing, walls, ceilings, and roofs $10,402 $145,860 $896
11,630
kWh
- $9,506
-
MMBtu
- - -
TOTAL RECOMMENDED $202,858 $1,527,089 $137,665
1,787,869
kWh
$233
-
kW-mo/yr
$18,240
-
MMBtu
$(-17,280.0) $10,000 $54,000
TOTAL IMPLEMENTED - - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Primary Raw Material Savings One-time Revenue or Avoided Cost Savings By-product Production Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs