Assessment Year | 2025 |
---|---|
Principal Product | pre-pined metal coils |
NAICS | 332812: Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers |
SIC | 3479: Coating, Engraving, and Allied Services, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 54 |
Plant Area |
94,900
ft2
|
Annual Production | 111,000
ton
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $62,426 | 4,559,157 |
kWh
|
$0.014 |
Electricity Demand | $61,776 | 17,140 |
kW-mo/yr
|
$3.60 |
Natural Gas | $198,965 | 83,964 |
MMBtu
|
$2.37 |
TOTAL YEARLY COSTS | $323,167 | |||
RECOMMENDED SAVINGS* | $151,308 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7224: Reduce space conditioning during non-working hours | $595 | $100 |
$183
13,057
kWh
|
- |
$412
-
MMBtu
|
|
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,303 | $4,500 |
$1,303
93,063
kWh
|
- | - | |
03 | 2.7135: Install occupancy sensors | $179 | $1,000 |
$179
12,780
kWh
|
- | - | |
04 | 2.2314: Replace heat treating oven with more efficient unit | $149,231 | $825,000 |
$(-13,247.0)
(-966,960)
kWh
|
$(-6,939.0)
-
kW-mo/yr
|
$169,417
-
MMBtu
|
|
TOTAL RECOMMENDED | $151,308 | $830,600 |
$(-11,582.0)
(-848,060)
kWh
|
$(-6,939.0)
-
kW-mo/yr
|
$169,829
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - |