Assessment Year | 2025 |
---|---|
Principal Product | plastic food storage bags |
NAICS | 322220: Paper Bag and Coated and Treated Paper Manufacturing |
SIC | 2673: Plastics, Foil, and Coated Paper Bags |
Sales Range | $100 M to 500M |
# of Employees | 460 |
Plant Area |
539,300
ft2
|
Annual Production | 150,000,000
lb
|
Production Hrs. Annual | 4,992
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $3,081,170 | 62,432,984 |
kWh
|
$0.049 | |
Electricity Demand | $787,295 | 110,722 |
kW-mo/yr
|
$7.11 | |
Natural Gas | $178,180 | 41,291 |
MMBtu
|
$4.32 | |
Waste Disposal Costs | |||||
Water Usage | $175,312 | 27,477 |
Tgal
|
$6.38 | |
Water Disposal | $34,963 | 27,477 |
Tgal
|
$1.27 | |
TOTAL YEARLY COSTS | $4,256,920 | ||||
RECOMMENDED SAVINGS* | $873,087 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $12,000 | $19,875 |
$12,000
244,905
kWh
|
- | |
02 | 2.2625: Chill water to the highest temperature possible | $24,783 | $28,280 |
$24,783
504,750
kWh
|
- | |
03 | 2.7221: Lower temperature during the winter season and vice-versa | $1,828 | - |
$1,828
37,314
kWh
|
- | |
04 | 2.9114: Use solar heat to make electricty | $428,798 | $4,387,498 |
$307,217
6,269,723
kWh
|
$121,581
-
kW-mo/yr
|
|
05 | 2.2622: Replace existing chiller with high efficiency model | $87,568 | $395,000 |
$66,928
1,365,887
kWh
|
$20,640
-
kW-mo/yr
|
|
06 | 2.4322: Use or replace with energy efficient substitutes | $318,110 | $818,754 |
$210,607
4,298,112
kWh
|
$107,503
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $873,087 | $5,649,407 |
$623,363
12,720,691
kWh
|
$249,724
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs