ITAC Assessment: MZ0381
ITAC logo
ITAC Assessment: MZ0381
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2025
Principal Product plastic food storage bags
NAICS 322220: Paper Bag and Coated and Treated Paper Manufacturing
SIC 2673: Plastics, Foil, and Coated Paper Bags
Sales Range $100
M
to 500
M
# of Employees 460
Plant Area 539,300
ft2
Annual Production 150,000,000
lb
Production Hrs. Annual 4,992
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $3,081,170 62,432,984
kWh
Electricity Demand $787,295 110,722
kW-mo/yr
Natural Gas $178,180 41,291
MMBtu
Waste Disposal Costs
Water Usage $175,312 27,477
Tgal
Water Disposal $34,963 27,477
Tgal
TOTAL YEARLY COSTS $4,256,920
RECOMMENDED SAVINGS* $873,087 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $12,000 $19,875 $12,000
244,905
kWh
-
02 2.2625: Chill water to the highest temperature possible $24,783 $28,280 $24,783
504,750
kWh
-
03 2.7221: Lower temperature during the winter season and vice-versa $1,828 - $1,828
37,314
kWh
-
04 2.9114: Use solar heat to make electricty $428,798 $4,387,498 $307,217
6,269,723
kWh
$121,581
-
kW-mo/yr
05 2.2622: Replace existing chiller with high efficiency model $87,568 $395,000 $66,928
1,365,887
kWh
$20,640
-
kW-mo/yr
06 2.4322: Use or replace with energy efficient substitutes $318,110 $818,754 $210,607
4,298,112
kWh
$107,503
-
kW-mo/yr
TOTAL RECOMMENDED $873,087 $5,649,407 $623,363
12,720,691
kWh
$249,724
-
kW-mo/yr
TOTAL IMPLEMENTED - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs