ITAC Assessment: MZ0380
ITAC logo
ITAC Assessment: MZ0380
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2025
Principal Product plastic trash bags
NAICS 322220: Paper Bag and Coated and Treated Paper Manufacturing
SIC 2673: Plastics, Foil, and Coated Paper Bags
Sales Range $10
M
to 50
M
# of Employees 453
Plant Area 670,000
ft2
Annual Production 1,994,000,000
pieces
Production Hrs. Annual 8,688
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $2,378,205 40,724,397
kWh
Electricity Demand $818,004 64,568
kW-mo/yr
Natural Gas $58,180 13,020
MMBtu
Waste Disposal Costs
Water Usage $168,559 29,836
Tgal
Water Disposal $127,012 29,836
Tgal
TOTAL YEARLY COSTS $3,549,960
RECOMMENDED SAVINGS* $469,315 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $105,308 $41,000 $105,308
1,815,662
kWh
-
02 2.2625: Chill water to the highest temperature possible $106,086 $31,591 $106,086
1,829,080
kWh
-
03 2.6127: Maintain air filters by cleaning or replacement $2,269 $500 $2,269
39,123
kWh
-
04 2.7224: Reduce space conditioning during non-working hours $11,856 $3,000 $11,856
204,410
kWh
-
05 2.7491: Insulate glazing, walls, ceilings, and roofs $10,506 $19,860 $10,506
181,133
kWh
-
06 2.4133: Use most efficient type of electric motors $81,337 $387,626 $62,484
1,077,321
kWh
$18,853
-
kW-mo/yr
07 2.7221: Lower temperature during the winter season and vice-versa $2,164 - $2,164
37,314
kWh
-
08 2.7135: Install occupancy sensors $4,713 $2,400 $4,713
81,305
kWh
-
09 2.2622: Replace existing chiller with high efficiency model $53,986 $195,000 $36,869
635,675
kWh
$17,117
-
kW-mo/yr
10 2.9114: Use solar heat to make electricty $37,784 $447,535 $37,784
651,453
kWh
-
11 2.4322: Use or replace with energy efficient substitutes $53,306 $145,600 $40,966
706,334
kWh
$12,340
-
kW-mo/yr
TOTAL RECOMMENDED $469,315 $1,274,112 $421,005
7,258,810
kWh
$48,310
-
kW-mo/yr
TOTAL IMPLEMENTED - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs