Assessment Year | 2025 |
---|---|
Principal Product | plastic trash bags |
NAICS | 322220: Paper Bag and Coated and Treated Paper Manufacturing |
SIC | 2673: Plastics, Foil, and Coated Paper Bags |
Sales Range | $10 M to 50M |
# of Employees | 453 |
Plant Area |
670,000
ft2
|
Annual Production | 1,994,000,000
pieces
|
Production Hrs. Annual | 8,688
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $2,378,205 | 40,724,397 |
kWh
|
$0.058 | |
Electricity Demand | $818,004 | 64,568 |
kW-mo/yr
|
$12.67 | |
Natural Gas | $58,180 | 13,020 |
MMBtu
|
$4.47 | |
Waste Disposal Costs | |||||
Water Usage | $168,559 | 29,836 |
Tgal
|
$5.65 | |
Water Disposal | $127,012 | 29,836 |
Tgal
|
$4.26 | |
TOTAL YEARLY COSTS | $3,549,960 | ||||
RECOMMENDED SAVINGS* | $469,315 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $105,308 | $41,000 |
$105,308
1,815,662
kWh
|
- | |
02 | 2.2625: Chill water to the highest temperature possible | $106,086 | $31,591 |
$106,086
1,829,080
kWh
|
- | |
03 | 2.6127: Maintain air filters by cleaning or replacement | $2,269 | $500 |
$2,269
39,123
kWh
|
- | |
04 | 2.7224: Reduce space conditioning during non-working hours | $11,856 | $3,000 |
$11,856
204,410
kWh
|
- | |
05 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $10,506 | $19,860 |
$10,506
181,133
kWh
|
- | |
06 | 2.4133: Use most efficient type of electric motors | $81,337 | $387,626 |
$62,484
1,077,321
kWh
|
$18,853
-
kW-mo/yr
|
|
07 | 2.7221: Lower temperature during the winter season and vice-versa | $2,164 | - |
$2,164
37,314
kWh
|
- | |
08 | 2.7135: Install occupancy sensors | $4,713 | $2,400 |
$4,713
81,305
kWh
|
- | |
09 | 2.2622: Replace existing chiller with high efficiency model | $53,986 | $195,000 |
$36,869
635,675
kWh
|
$17,117
-
kW-mo/yr
|
|
10 | 2.9114: Use solar heat to make electricty | $37,784 | $447,535 |
$37,784
651,453
kWh
|
- | |
11 | 2.4322: Use or replace with energy efficient substitutes | $53,306 | $145,600 |
$40,966
706,334
kWh
|
$12,340
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $469,315 | $1,274,112 |
$421,005
7,258,810
kWh
|
$48,310
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs