Assessment Year | 2025 |
---|---|
Principal Product | fabricated structural steel |
NAICS | 332312: Fabricated Structural Metal Manufacturing |
SIC | 3441: Fabricated Structural Metal |
Sales Range | $50 M to 100M |
# of Employees | 170 |
Plant Area |
328,000
ft2
|
Annual Production | 12,000
ton
|
Production Hrs. Annual | 4,500
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $276,008 | 2,524,398 |
kWh
|
$0.11 |
Electricity Demand | $39,435 | 12,814 |
kW-mo/yr
|
$3.08 |
Natural Gas | $21,834 | 3,934 |
MMBtu
|
$5.55 |
TOTAL YEARLY COSTS | $337,277 | |||
RECOMMENDED SAVINGS* | $626,962 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.2437: Recover waste heat from equipment | $19,447 | $22,100 | - | - |
$19,447
-
MMBtu
|
- | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,208 | $400 |
$2,053
18,832
kWh
|
$155
-
kW-mo/yr
|
- | - | |
03 | 2.7135: Install occupancy sensors | $1,090 | $1,405 |
$1,090
10,000
kWh
|
- | - | - | |
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $12,542 | $13,100 |
$12,542
115,066
kWh
|
- | - | - | |
05 | 2.7135: Install occupancy sensors | $295 | $2,100 |
$295
2,705
kWh
|
- | - | - | |
06 | 2.7221: Lower temperature during the winter season and vice-versa | $4,865 | - |
$3,084
28,296
kWh
|
- |
$1,781
-
MMBtu
|
- | |
07 | 2.9114: Use solar heat to make electricty | $34,746 | $214,502 |
$33,527
307,589
kWh
|
$1,219
-
kW-mo/yr
|
- | - | |
08 | 2.4324: Replace hydraulic / pneumatic equipment with electric equipment | $7,435 | $12,750 |
$6,357
58,320
kWh
|
$1,078
-
kW-mo/yr
|
- | - | |
09 | 2.4321: Upgrade obsolete equipment | $544,334 | $2,410,000 |
$6,334
58,114
kWh
|
- | - | $538,000 | |
TOTAL RECOMMENDED | $626,962 | $2,676,357 |
$65,282
598,922
kWh
|
$2,452
-
kW-mo/yr
|
$21,228
-
MMBtu
|
$538,000 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs