Assessment Year | 2024 |
---|---|
Principal Product | plastic dispensers |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 500 |
Plant Area |
465,000
ft2
|
Annual Production | 378,000,000
lb
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $1,998,908 | 30,643,841 |
kWh
|
$0.065 | |
Electricity Demand | $462,887 | 55,620 |
kW-mo/yr
|
$8.32 | |
Natural Gas | $51,388 | 11,451 |
MMBtu
|
$4.49 | |
Waste Disposal Costs | |||||
Water Usage | $172,392 | 12,557 |
Tgal
|
$13.73 | |
TOTAL YEARLY COSTS | $2,685,575 | ||||
RECOMMENDED SAVINGS* | $71,014 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $18,120 | $1,100 |
$14,429
222,044
kWh
|
$3,691
-
kW-mo/yr
|
|
02 | 2.4239: Eliminate or reduce compressed air usage | $6,143 | $20,027 |
$6,143
94,500
kWh
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,000 | $300 |
$1,702
26,179
kWh
|
$298
-
kW-mo/yr
|
|
04 | 2.7135: Install occupancy sensors | $984 | $700 |
$984
15,137
kWh
|
- | |
05 | 2.7232: Replace existing hvac unit with high efficiency model | $43,767 | $294,662 |
$27,069
416,455
kWh
|
$16,698
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $71,014 | $316,789 |
$50,327
774,315
kWh
|
$20,687
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs