| Assessment Year | 2023 |
|---|---|
| Principal Product | plastic sheet and roll stock |
| NAICS | 326130: Laminated Plastics Plate, Sheet (except Packaging), and Shape Manufacturing |
| SIC | 3083: Laminated Plastics Plate, Sheet, and Profile Shapes |
| Sales Range | $10 M to 50M |
| # of Employees | 49 |
| Plant Area |
131,000
ft2
|
| Annual Production | 16,000,000
lb
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Missouri |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $702,636 | 8,074,706 |
kWh
|
$0.087 | |
| Natural Gas | $35,584 | 2,478 |
MMBtu
|
$14.36 | |
| Waste Disposal Costs | |||||
| Water Usage | $11,448 | 2,698 |
Tgal
|
$4.24 | |
| Water Disposal | $6,371 | 1,469 |
Tgal
|
$4.34 | |
| TOTAL YEARLY COSTS | $756,039 | ||||
| RECOMMENDED SAVINGS* | $86,867 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $12,517 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $4,815 | $440 |
$4,815
55,352
kWh
|
- | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,082 | $600 |
$3,082
31,885
kWh
|
- | |
| 03 | 2.3191: Use demand controller or load shedder | $8,826 | $2,520 | - | $8,826 | |
| 04 | 2.7135: Install occupancy sensors | $9,435 | $9,200 |
$9,435
111,005
kWh
|
- | |
| 05 | 2.9114: Use solar heat to make electricty | $60,709 | $140,732 |
$60,709
697,812
kWh
|
- | |
| TOTAL RECOMMENDED | $86,867 | $153,492 |
$78,041
896,054
kWh
|
$8,826 | ||
| TOTAL IMPLEMENTED | $12,517 | $9,800 |
$12,517
142,890
kWh
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs