| Assessment Year | 2023 |
|---|---|
| Principal Product | Metal food cans |
| NAICS | 332431: Metal Can Manufacturing |
| SIC | 3411: Metal Cans |
| Sales Range | $50 M to 100M |
| # of Employees | 75 |
| Plant Area |
210,000
ft2
|
| Annual Production | 1,700,000,000
pieces
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Missouri |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $721,479 | 14,605,004 |
kWh
|
$0.049 | |
| Electricity Demand | $246,404 | 23,046 |
kW-mo/yr
|
$10.69 | |
| Natural Gas | $523,876 | 75,511 |
MMBtu
|
$6.94 | |
| Waste Disposal Costs | |||||
| Water Usage | $99,727 | 30,964 |
Tgal
|
$3.22 | |
| TOTAL YEARLY COSTS | $1,591,486 | ||||
| RECOMMENDED SAVINGS* | $215,101 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $47,920 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7135: Install occupancy sensors | $1,963 | $2,020 |
$1,963
39,262
kWh
|
- | - | |
| 02 | 2.4239: Eliminate or reduce compressed air usage | $14,175 | $53,900 |
$10,964
219,280
kWh
|
$3,211
-
kW-mo/yr
|
- | |
| 03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $774 | - |
$593
11,850
kWh
|
$181
-
kW-mo/yr
|
- | |
| 04 | 2.4239: Eliminate or reduce compressed air usage | $11,688 | $5,500 |
$9,041
180,814
kWh
|
$2,647
-
kW-mo/yr
|
- | |
| 05 | 2.2437: Recover waste heat from equipment | $31,782 | $11,200 | - | - |
$31,782
-
MMBtu
|
|
| 06 | 2.9114: Use solar heat to make electricty | $154,719 | $1,434,375 |
$105,447
2,108,938
kWh
|
$49,272
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $215,101 | $1,506,995 |
$128,008
2,560,144
kWh
|
$55,311
-
kW-mo/yr
|
$31,782
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $47,920 | $67,120 |
$12,927
258,542
kWh
|
$3,211
-
kW-mo/yr
|
$31,782
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs