Assessment Year | 2020 |
---|---|
Principal Product | Wine and bourbon barrel staves and headings |
NAICS | 321920: Wood Container and Pallet Manufacturing |
SIC | 2449: Wood Containers, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 150 |
Plant Area |
70,000
ft2
|
Annual Production | 93,600
pieces
|
Production Hrs. Annual | 4,680
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $334,018 | 5,095,280 |
kWh
|
$0.066 |
Electricity Demand | $40,320 | 12,590 |
kW-mo/yr
|
$3.20 |
TOTAL YEARLY COSTS | $374,338 | |||
RECOMMENDED SAVINGS* | $37,398 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $33,624 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $22,041 | $51,700 |
$17,574
266,269
kWh
|
$4,467
-
kW-mo/yr
|
|
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $773 | $320 |
$680
10,299
kWh
|
$93
-
kW-mo/yr
|
|
03 | 2.3212: Optimize plant power factor | $7,129 | $24,780 | - |
$7,129
-
kW-mo/yr
|
|
04 | 2.7135: Install occupancy sensors | $320 | $840 |
$320
4,847
kWh
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,880 | $2,595 |
$1,654
25,055
kWh
|
$226
-
kW-mo/yr
|
|
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,857 | $350 |
$1,857
28,135
kWh
|
- | |
07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,001 | $1,050 |
$2,640
40,004
kWh
|
$361
-
kW-mo/yr
|
|
08 | 2.6127: Maintain air filters by cleaning or replacement | $397 | $300 |
$397
6,017
kWh
|
- | |
TOTAL RECOMMENDED | $37,398 | $81,935 |
$25,122
380,626
kWh
|
$12,276
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $33,624 | $80,565 |
$21,802
330,323
kWh
|
$11,822
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs