Assessment Year 2020
Principal Product corrugated cardboard packaging materials
NAICS 322211: Corrugated and Solid Fiber Box Manufacturing
SIC 2653: Corrugated and Solid Fiber Boxes
Sales Range $10
M
to 50
M
# of Employees 98
Plant Area 435,000
ft2
Annual Production 450,000,000
lb
Production Hrs. Annual 6,072
hrs
Location (State) Missouri

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $463,717 6,197,150
kWh
Electricity Demand $58,446 20,276
kW-mo/yr
TOTAL YEARLY COSTS $522,163
RECOMMENDED SAVINGS* $52,005 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $27,697

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings One-time Revenue or Avoided Cost Savings
01 2.7144: Install spectral reflectors / delamp $2,928 $750 $863
11,519
kWh
$65
-
kW-mo/yr
$2,000
02 2.7135: Install occupancy sensors $14,842 $19,695 $14,842
197,899
kWh
- -
03 2.4111: Utilize energy-efficient belts and other improved mechanisms $5,682 $340 $5,281
70,417
kWh
$401
-
kW-mo/yr
-
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $4,835 $640 $4,495
59,931
kWh
$340
-
kW-mo/yr
-
05 2.4231: Reduce the pressure of compressed air to the minimum required $5,092 $320 $4,733
63,108
kWh
$359
-
kW-mo/yr
-
06 2.6242: Minimize operation of equipment maintained in standby condition $18,626 $1,400 $15,757
210,089
kWh
$2,869
-
kW-mo/yr
-
TOTAL RECOMMENDED $52,005 $23,145 $45,971
612,963
kWh
$4,034
-
kW-mo/yr
$2,000
TOTAL IMPLEMENTED $27,697 $21,405 $24,933
332,457
kWh
$764
-
kW-mo/yr
$2,000
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs