Assessment Year | 2017 |
---|---|
Principal Product | Fabricated structural steel trusses for bridges |
NAICS | 332312: Fabricated Structural Metal Manufacturing |
SIC | 3441: Fabricated Structural Metal |
Sales Range | $1 M to 5M |
# of Employees | 170 |
Plant Area |
320,000
ft2
|
Annual Production | 1,000
pieces
|
Production Hrs. Annual | 4,000
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $336,010 | 2,354,330 |
kWh
|
$0.14 |
Electricity Demand | $30,509 | 12,873 |
kW-mo/yr
|
$2.37 |
Natural Gas | $3,869 | 881 |
MMBtu
|
$4.39 |
TOTAL YEARLY COSTS | $370,388 | |||
RECOMMENDED SAVINGS* | $34,645 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $34,645 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $6,680 | - |
$6,680
47,042
kWh
|
- | - | - | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $605 | - |
$605
4,207
kWh
|
- | - | - | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $70 | - |
$70
492
kWh
|
- | - | - | |
04 | 2.2437: Recover waste heat from equipment | $3,933 | $1,539 | - | - |
$3,933
-
MMBtu
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $18,398 | $22,603 |
$13,562
95,040
kWh
|
$676
-
kW-mo/yr
|
- | $4,160 | |
06 | 2.7111: Reduce illumination to minimum necessary levels | $403 | $100 |
$384
2,688
kWh
|
$19
-
kW-mo/yr
|
- | - | |
07 | 2.7135: Install occupancy sensors | $1,231 | $950 |
$1,142
8,005
kWh
|
$88
-
kW-mo/yr
|
- | - | |
08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,326 | $200 |
$3,236
22,672
kWh
|
$90
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $34,645 | $25,392 |
$25,679
180,146
kWh
|
$874
-
kW-mo/yr
|
$3,933
-
MMBtu
|
$4,160 | ||
TOTAL IMPLEMENTED | $34,645 | $25,392 |
$25,679
180,146
kWh
|
$874
-
kW-mo/yr
|
$3,933
-
MMBtu
|
$4,160 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs