| Assessment Year | 2015 |
|---|---|
| Principal Product | infrared panel and oven |
| NAICS | 333994: Industrial Process Furnace and Oven Manufacturing |
| SIC | 3433: Heating Equipment, Except Electric and Warm Air Furnaces |
| Sales Range | $5 M to 10M |
| # of Employees | 25 |
| Plant Area |
25,000
ft2
|
| Annual Production | 5,000
pieces
|
| Production Hrs. Annual | 3,150
hrs
|
| Location (State) | Missouri |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $81,917 | 892,800 |
kWh
|
$0.092 |
| Electricity Demand | $29,414 | 10,782 |
kW-mo/yr
|
$2.73 |
| Natural Gas | $1,248 | 96 |
MMBtu
|
$13.00 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $7,109 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,002 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7425: Clean or color roof to reduce solar load | $1,679 | $10,800 |
$1,507
16,425
kWh
|
$172
-
kW-mo/yr
|
|
| 02 | 2.4239: Eliminate or reduce compressed air usage | $1,588 | $1,200 |
$1,520
16,561
kWh
|
$68
-
kW-mo/yr
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,414 | $11,400 |
$2,168
23,625
kWh
|
$246
-
kW-mo/yr
|
|
| 04 | 2.7135: Install occupancy sensors | $1,428 | $500 |
$1,428
15,566
kWh
|
- | |
| TOTAL RECOMMENDED | $7,109 | $23,900 |
$6,623
72,177
kWh
|
$486
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | $4,002 | $12,600 |
$3,688
40,186
kWh
|
$314
-
kW-mo/yr
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs