Assessment Year | 2009 |
---|---|
Principal Product | large plastic pipe |
NAICS | 326122: Plastics Pipe and Pipe Fitting Manufacturing |
SIC | 3084: Plastics Pipe |
Sales Range | $10 M to 50M |
# of Employees | 46 |
Plant Area |
77,600
ft2
|
Annual Production | 6,000,000
lb
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $937,875 | 13,277,112 |
kWh
|
$0.071 |
Natural Gas | $51,420 | 23,750 |
MMBtu
|
$2.17 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $226,578 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $223,569 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,595 | $20,400 |
$1,085
15,375
kWh
|
$3,510
-
kW-mo/yr
|
- | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,634 | $860 |
$1,314
14,061
kWh
|
$320
-
kW-mo/yr
|
- | |
03 | 2.7135: Install occupancy sensors | $2,319 | $480 |
$1,782
17,640
kWh
|
$537
-
kW-mo/yr
|
- | |
04 | 2.7492: Use proper thickness of insulation on building envelope | $627 | $1,800 | - | - |
$627
-
MMBtu
|
|
05 | 2.7492: Use proper thickness of insulation on building envelope | $7,387 | $3,600 |
$7,387
104,639
kWh
|
- | - | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,995 | $1 |
$3,995
51,660
kWh
|
- | - | |
07 | 2.2437: Recover waste heat from equipment | $3,009 | $500 | - | - |
$3,009
-
MMBtu
|
|
08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $192,075 | $12,080 |
$192,075
2,747,514
kWh
|
- | - | |
09 | 2.1211: Move boiler to more efficient location | $10,937 | $3,000 | - | - |
$10,937
-
MMBtu
|
|
TOTAL RECOMMENDED | $226,578 | $42,721 |
$207,638
2,950,889
kWh
|
$4,367
-
kW-mo/yr
|
$14,573
-
MMBtu
|
||
TOTAL IMPLEMENTED | $223,569 | $42,221 |
$207,638
2,950,889
kWh
|
$4,367
-
kW-mo/yr
|
$11,564
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs