ITAC Assessment: MZ0032
ITAC logo
ITAC Assessment: MZ0032
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2008
Principal Product Brackets for car seats
NAICS 332510: Hardware Manufacturing
SIC 3429: Hardware, Not Elsewhere Classified
Sales Range $100
M
to 500
M
# of Employees 120
Plant Area 76,000
ft2
Annual Production 45,000,000
units
Production Hrs. Annual 5,760
hrs
Location (State) Missouri

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $189,508 3,440,000
kWh
Natural Gas $28,193 20,720
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $3,567 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $2,916

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.7135: Install occupancy sensors $1,456 $712 $1,456
24,261
kWh
02 2.7135: Install occupancy sensors $651 $356 $651
10,854
kWh
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $703 - $703
10,907
kWh
04 2.6127: Maintain air filters by cleaning or replacement $757 $300 $757
12,627
kWh
TOTAL RECOMMENDED $3,567 $1,368 $3,567
58,649
kWh
TOTAL IMPLEMENTED $2,916 $1,012 $2,916
47,795
kWh
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs