Assessment Year | 2008 |
---|---|
Principal Product | Electrical meter sockets and related components, powder coating |
NAICS | 335931: Current-Carrying Wiring Device Manufacturing |
SIC | 3643: Current-Carrying Wiring Devices |
Sales Range | $10 M to 50M |
# of Employees | 190 |
Plant Area |
96,000
ft2
|
Annual Production | 230,000
pieces
|
Production Hrs. Annual | 4,000
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $154,114 | 2,583,568 |
kWh
|
$0.060 |
Natural Gas | $151,960 | 18,795 |
MMBtu
|
$8.09 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $7,606 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,032 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.1135: Repair furnaces and oven doors so that they seal efficiently | $62 | $200 | - |
$62
-
MMBtu
|
|
02 | 2.1122: Re-size charging openings or add a movable door on equipment | $222 | $1,400 | - |
$222
-
MMBtu
|
|
03 | 2.2515: Use optimum thickness insulation | $34 | $300 | - |
$34
-
MMBtu
|
|
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,936 | $1,400 |
$2,936
43,300
kWh
|
- | |
05 | 2.2447: Heat water with exhaust heat | $4,352 | $10,000 | - |
$4,352
-
MMBtu
|
|
TOTAL RECOMMENDED | $7,606 | $13,300 |
$2,936
43,300
kWh
|
$4,670
-
MMBtu
|
||
TOTAL IMPLEMENTED | $3,032 | $1,900 |
$2,936
43,300
kWh
|
$96
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs