Assessment Year | 2007 |
---|---|
Principal Product | wood barrels |
NAICS | 321113: Sawmills |
SIC | 2421: Sawmills and Planing Mills, General |
Sales Range | $10 M to 50M |
# of Employees | 330 |
Plant Area |
310,000
ft2
|
Annual Production | 100,000
units
|
Production Hrs. Annual | 2,500
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,009,801 | 17,455,204 |
kWh
|
$0.058 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $35,007 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $35,007 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,272 | - |
$1,272
10,896
kWh
|
|
02 | 2.7135: Install occupancy sensors | $3,576 | $2,450 |
$3,576
61,660
kWh
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $13,922 | $1,150 |
$13,922
130,234
kWh
|
|
04 | 2.7111: Reduce illumination to minimum necessary levels | $2,310 | - |
$2,310
39,840
kWh
|
|
05 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $13,927 | $2,500 |
$13,927
3,203
kWh
|
|
TOTAL RECOMMENDED | $35,007 | $6,100 |
$35,007
245,833
kWh
|
||
TOTAL IMPLEMENTED | $35,007 | $6,100 |
$35,007
245,833
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs