| Assessment Year | 2026 |
|---|---|
| Principal Product | Research lab |
| NAICS | 611310: Colleges, Universities, and Professional Schools |
| SIC | 8221: Colleges, Universities, and Professional Schools |
| Sales Range | less than $500 k |
| # of Employees | 50 |
| Plant Area |
66,302
ft2
|
| Annual Production | 1
units
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $78,173 | 1,615,247 |
kWh
|
$0.048 |
| Electricity Demand | $38,485 | 5,673 |
kW-mo/yr
|
$6.78 |
| Electricity Fees | $3,608 | - |
|
- |
| Other Gas | $721 | 1 |
MMBtu
|
$721.00 |
| Other Energy | $35,315 | 4,107 |
MMBtu
|
$8.60 |
| TOTAL YEARLY COSTS | $156,302 | |||
| RECOMMENDED SAVINGS* | $23,408 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $19,704 | $60,384 |
$13,352
278,182
kWh
|
$6,352
-
kW-mo/yr
|
- | |
| 02 | 2.7243: Improve air circulation with destratification fans / other methods | $1,048 | $4,221 | - | - |
$1,048
-
MMBtu
|
|
| 03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $724 | - |
$557
11,597
kWh
|
$168
-
kW-mo/yr
|
- | |
| 04 | 2.7135: Install occupancy sensors | $685 | $752 |
$639
13,310
kWh
|
$46
-
kW-mo/yr
|
- | |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $486 | $272 |
$282
5,878
kWh
|
$204
-
kW-mo/yr
|
- | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $370 | $2,050 |
$309
6,570
kWh
|
$61
-
kW-mo/yr
|
- | |
| 07 | 2.7134: Use photocell controls | $120 | $585 |
$100
2,093
kWh
|
$19
-
kW-mo/yr
|
- | |
| 08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $188 | $100 |
$158
3,253
kWh
|
$30
-
kW-mo/yr
|
- | |
| 09 | 2.2136: Install / repair insulation on steam lines | $83 | $114 | - | - |
$83
-
MMBtu
|
|
| TOTAL RECOMMENDED | $23,408 | $68,478 |
$15,397
320,883
kWh
|
$6,880
-
kW-mo/yr
|
$1,131
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Other Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs