| Assessment Year | 2025 |
|---|---|
| Principal Product | required |
| NAICS | 611310: Colleges, Universities, and Professional Schools |
| SIC | 8221: Colleges, Universities, and Professional Schools |
| Sales Range | less than $500 k |
| # of Employees | 250 |
| Plant Area |
50,000
ft2
|
| Annual Production | 1
pieces
|
| Production Hrs. Annual | 2,340
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $118,804 | 1,466,719 |
kWh
|
$0.081 | |
| Natural Gas | $43,262 | 8,624 |
MMBtu
|
$5.02 | |
| Waste Disposal Costs | |||||
| Water Usage | $23,073 | 2,857 |
Tgal
|
$8.08 | |
| TOTAL YEARLY COSTS | $185,139 | ||||
| RECOMMENDED SAVINGS* | $4,522 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7135: Install occupancy sensors | $4,360 | $360 |
$4,360
53,821
kWh
|
- | |
| 02 | 2.7134: Use photocell controls | $122 | $893 |
$122
1,503
kWh
|
- | |
| 03 | 2.2136: Install / repair insulation on steam lines | $40 | $147 | - |
$40
-
MMBtu
|
|
| TOTAL RECOMMENDED | $4,522 | $1,400 |
$4,482
55,324
kWh
|
$40
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs