| Assessment Year | 2026 |
|---|---|
| Principal Product | Glass Auto Parts |
| NAICS | 327215: Glass Product Manufacturing Made of Purchased Glass |
| SIC | 3231: Glass Products, Made of Purchased Glass |
| Sales Range | $100 M to 500M |
| # of Employees | 250 |
| Plant Area |
325,000
ft2
|
| Annual Production | 1,600,000
units
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Indiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $1,995,951 | 51,877,000 |
kWh
|
$0.038 | |
| Electricity Demand | $1,703,170 | 99,601 |
kW-mo/yr
|
$17.10 | |
| Electricity Fees | $3,607 | - |
|
- | |
| Natural Gas | $27,436 | 6,086 |
MMBtu
|
$4.51 | |
| Other Energy | $23,808 | 1 |
MMBtu
|
$23,808.00 | |
| Waste Disposal Costs | |||||
| Water Usage | $138,021 | 32,103 |
Tgal
|
$4.30 | |
| TOTAL YEARLY COSTS | $3,891,993 | ||||
| RECOMMENDED SAVINGS* | $146,968 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $64,082 | $76,821 |
$39,644
1,043,264
kWh
|
$24,438
-
kW-mo/yr
|
|
| 02 | 2.9114: Use solar heat to make electricty | $66,138 | $1,100,000 |
$26,675
701,965
kWh
|
$39,464
-
kW-mo/yr
|
|
| 03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $12,746 | - |
$7,855
206,717
kWh
|
$4,891
-
kW-mo/yr
|
|
| 04 | 2.6218: Turn off equipment when not in use | $32 | - |
$20
526
kWh
|
$12
-
kW-mo/yr
|
|
| 05 | 2.7111: Reduce illumination to minimum necessary levels | $258 | - |
$160
4,205
kWh
|
$98
-
kW-mo/yr
|
|
| 06 | 2.7134: Use photocell controls | $88 | $124 |
$54
1,433
kWh
|
$34
-
kW-mo/yr
|
|
| 07 | 2.7135: Install occupancy sensors | $322 | $1,128 |
$119
3,134
kWh
|
$203
-
kW-mo/yr
|
|
| 08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,302 | $1,530 |
$1,837
48,355
kWh
|
$1,465
-
kW-mo/yr
|
|
| TOTAL RECOMMENDED | $146,968 | $1,179,603 |
$76,364
2,009,598
kWh
|
$70,604
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs