| Assessment Year | 2025 |
|---|---|
| Principal Product | Copper Carbonate |
| NAICS | 325180: Other Basic Inorganic Chemical Manufacturing |
| SIC | 2491: Wood Preserving |
| Sales Range | less than $500 k |
| # of Employees | 60 |
| Plant Area |
40,000
ft2
|
| Annual Production | 65,000,000
lb
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $708,241 | 8,283,705 |
kWh
|
$0.085 |
| Electricity Demand | $210,900 | 32,985 |
kW-mo/yr
|
$6.39 |
| Electricity Fees | $29,110 | - |
|
- |
| Natural Gas | $1,541,831 | 313,795 |
MMBtu
|
$4.91 |
| Other Gas | $337,590 | 1 |
MMBtu
|
$337,589.72 |
| TOTAL YEARLY COSTS | $2,827,672 | |||
| RECOMMENDED SAVINGS* | $165,491 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.2424: Use heat in flue gases to preheat products or materials | $161,393 | $126,876 | - | - |
$161,393
-
MMBtu
|
- | |
| 02 | 2.7135: Install occupancy sensors | $1,481 | $960 |
$1,290
15,177
kWh
|
$191
-
kW-mo/yr
|
- | - | |
| 03 | 2.2437: Recover waste heat from equipment | $38 | $271 | - | - |
$38
-
MMBtu
|
- | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,343 | $9,811 |
$1,169
13,758
kWh
|
$173
-
kW-mo/yr
|
- | - | |
| 05 | 2.7134: Use photocell controls | $138 | $404 |
$89
1,052
kWh
|
$49
-
kW-mo/yr
|
- | - | |
| 06 | 2.7221: Lower temperature during the winter season and vice-versa | $228 | - |
$105
1,235
kWh
|
$123
-
kW-mo/yr
|
- | - | |
| 07 | 2.7221: Lower temperature during the winter season and vice-versa | $231 | - |
$160
1,882
kWh
|
$71
-
kW-mo/yr
|
- | - | |
| 08 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $640 | - | - | - | - | $640 | |
| TOTAL RECOMMENDED | $165,491 | $138,322 |
$2,814
33,103
kWh
|
$607
-
kW-mo/yr
|
$161,431
-
MMBtu
|
$640 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs