ITAC Assessment: MU0021
ITAC logo
ITAC Assessment: MU0021
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2023
Principal Product Tooling products and manufacturing equipment
NAICS 333519: Rolling Mill and Other Metalworking Machinery Manufacturing
SIC 3569: General Industrial Machinery and Equipment, Not Elsewhere
Sales Range $10
M
to 50
M
# of Employees 110
Plant Area 69,930
ft2
Annual Production 8,000
pieces
Production Hrs. Annual 2,600
hrs
Location (State) Michigan

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $79,205 552,180
kWh
Electricity Fees $9,015 -
Natural Gas $11,241 1,383
MMBtu
TOTAL YEARLY COSTS $99,461
RECOMMENDED SAVINGS* $13,790 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $11,438

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Fees Savings Personnel Changes Savings
01 2.4322: Use or replace with energy efficient substitutes $6,907 $21,510 $907
6,479
kWh
- $6,000
02 3.1161: Eliminate/reduce an operation $588 - $588
4,200
kWh
- -
03 2.6218: Turn off equipment when not in use $226 $200 $226
1,615
kWh
- -
04 2.8121: Apply for tax-free status for energy purchases $2,126 $1,367 - $2,126 -
05 2.7135: Install occupancy sensors $3,420 $1,933 $3,420
24,427
kWh
- -
06 2.6218: Turn off equipment when not in use $85 $80 $85
605
kWh
- -
07 2.4133: Use most efficient type of electric motors $438 $1,877 $438
3,131
kWh
- -
TOTAL RECOMMENDED $13,790 $26,966 $5,664
40,457
kWh
$2,126 $6,000
TOTAL IMPLEMENTED $11,438 $25,400 $5,438
38,842
kWh
- $6,000
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Fees Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs