ITAC Assessment: MS0470
ITAC logo
ITAC Assessment: MS0470
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2026
Principal Product Thermoplastic Parts
NAICS 326199: All Other Plastics Product Manufacturing
SIC 3429: Hardware, Not Elsewhere Classified
Sales Range $1
M
to 5
M
# of Employees 10
Plant Area 22,500
ft2
Annual Production 10,000
pieces
Production Hrs. Annual 2,750
hrs
Location (State) Mississippi

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $32,258 439,760
kWh
Electricity Demand $6,387 2,349
kW-mo/yr
Electricity Fees $708 -
LPG $327 16
MMBtu
Waste Disposal Costs
Water Usage $324 39
Tgal
Water Disposal $382 39
Tgal
TOTAL YEARLY COSTS $40,386
RECOMMENDED SAVINGS* $7,937 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Solid Waste (non-haz) Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $159 $540 $159
2,178
kWh
- -
02 2.7135: Install occupancy sensors $491 $2,310 $491
6,720
kWh
- -
03 2.4231: Reduce the pressure of compressed air to the minimum required $50 - $50
677
kWh
- -
04 2.7142: Utilize higher efficiency lamps and/or ballasts $979 $1,323 $850
11,637
kWh
$129
-
kW-mo/yr
-
05 3.5248: Separate and recycle scrap metal to foundry or for sale $10 - - - $10
-
lb
06 2.7224: Reduce space conditioning during non-working hours $6,122 - $6,122
83,630
kWh
- -
07 2.2625: Chill water to the highest temperature possible $126 - $126
1,726
kWh
- -
TOTAL RECOMMENDED $7,937 $4,173 $7,798
106,568
kWh
$129
-
kW-mo/yr
$10
-
lb
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Solid Waste (non-haz) Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs