| Assessment Year | 2026 |
|---|---|
| Principal Product | Engine Components |
| NAICS | 333618: Other Engine Equipment Manufacturing |
| SIC | 3519: Internal Combustion Engines, Not Elsewhere Classified |
| Sales Range | $100 M to 500M |
| # of Employees | 85 |
| Plant Area |
230,000
ft2
|
| Annual Production | 50,000
units
|
| Production Hrs. Annual | 4,500
hrs
|
| Location (State) | Mississippi |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $733,996 | 13,197,643 |
kWh
|
$0.056 | |
| Electricity Demand | $238,908 | 36,881 |
kW-mo/yr
|
$6.48 | |
| Electricity Fees | $2,838 | - |
|
- | |
| Natural Gas | $107,906 | 8,927 |
MMBtu
|
$12.09 | |
| Waste Disposal Costs | |||||
| Water Usage | $8,505 | 1,189 |
Tgal
|
$7.15 | |
| Water Disposal | $8,225 | 1,189 |
Tgal
|
$6.92 | |
| TOTAL YEARLY COSTS | $1,100,378 | ||||
| RECOMMENDED SAVINGS* | $152,796 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.3212: Optimize plant power factor | $41,807 | $88,391 | - |
$41,807
-
kW-mo/yr
|
- | - | |
| 02 | 2.8114: Change rate schedules or other changes in utility service | $44,517 | - | - | - | $44,517 | - | |
| 03 | 2.8112: Combine utility meters | $300 | - | - | - | - | $300 | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,210 | $2,244 |
$4,210
75,719
kWh
|
- | - | - | |
| 05 | 2.4324: Replace hydraulic / pneumatic equipment with electric equipment | $42,861 | $712 |
$42,861
783,282
kWh
|
- | - | - | |
| 06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $19,101 | $93,000 |
$19,101
343,538
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $152,796 | $184,347 |
$66,172
1,202,539
kWh
|
$41,807
-
kW-mo/yr
|
$44,517 | $300 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs