| Assessment Year | 2025 |
|---|---|
| Principal Product | Military Vehicles |
| NAICS | 336992: Military Armored Vehicle, Tank, and Tank Component Manufacturing |
| SIC | 3711: Motor Vehicles and Passenger Car Bodies |
| Sales Range | $50 M to 100M |
| # of Employees | 166 |
| Plant Area |
650,000
ft2
|
| Annual Production | 832
units
|
| Production Hrs. Annual | 2,128
hrs
|
| Location (State) | Mississippi |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $490,178 | 3,559,300 |
kWh
|
$0.14 | |
| Electricity Demand | $219,101 | 13,738 |
kW-mo/yr
|
$15.95 | |
| Electricity Fees | $25,992 | - |
|
- | |
| Natural Gas | $53,715 | 10,965 |
MMBtu
|
$4.90 | |
| LPG | $34,082 | 1,072 |
MMBtu
|
$31.80 | |
| Other Gas | $9,847 | 468 |
MMBtu
|
$21.04 | |
| Waste Disposal Costs | |||||
| Water Usage | $5,956 | 1,677 |
Tgal
|
$3.55 | |
| Water Disposal | $5,490 | 1,677 |
Tgal
|
$3.27 | |
| TOTAL YEARLY COSTS | $844,359 | ||||
| RECOMMENDED SAVINGS* | $324,237 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | LPG Savings | Other Gas Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.9114: Use solar heat to make electricty | $217,439 | $973,557 |
$188,649
1,370,000
kWh
|
$28,790
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.7229: Air condition only space necessary | $48,357 | $35,751 |
$(-158.1)
(-1,129)
kWh
|
- |
$48,515
-
MMBtu
|
- | - | |
| 03 | 2.7495: Install replacement doors | $10,741 | $15,697 | - | - |
$10,741
-
MMBtu
|
- | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $15,225 | $34,284 |
$14,643
104,595
kWh
|
$582
-
kW-mo/yr
|
- | - | - | |
| 05 | 2.1321: Replace fossil fuel equipment with electrical equipment | $24,271 | $200,000 |
$(-9,811.2)
(-70,080)
kWh
|
- | - |
$34,082
-
MMBtu
|
- | |
| 06 | 2.1321: Replace fossil fuel equipment with electrical equipment | $8,205 | $72,000 |
$(-1,641.8)
(-11,727)
kWh
|
- | - | - |
$9,847
-
MMBtu
|
|
| TOTAL RECOMMENDED | $324,237 | $1,331,288 |
$191,681
1,391,659
kWh
|
$29,372
-
kW-mo/yr
|
$59,256
-
MMBtu
|
$34,082
-
MMBtu
|
$9,847
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | LPG Savings | Other Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs