Assessment Year | 2025 |
---|---|
Principal Product | Mattresses |
NAICS | 337910: Mattress Manufacturing |
SIC | 2515: Mattresses, Foundations, and Convertible Beds |
Sales Range | $50 M to 100M |
# of Employees | 57 |
Plant Area |
285,000
ft2
|
Annual Production | 1,000,000
units
|
Production Hrs. Annual | 4,992
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $78,971 | 1,100,400 |
kWh
|
$0.072 | |
Electricity Demand | $41,868 | 3,176 |
kW-mo/yr
|
$13.18 | |
Natural Gas | $43,377 | 5,553 |
MMBtu
|
$7.81 | |
Waste Disposal Costs | |||||
Water Usage | $1,288 | 309 |
Tgal
|
$4.17 | |
TOTAL YEARLY COSTS | $165,504 | ||||
RECOMMENDED SAVINGS* | $29,192 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $28,668 | $282,366 |
$21,576
299,664
kWh
|
$7,092
-
kW-mo/yr
|
|
02 | 2.7135: Install occupancy sensors | $419 | $956 |
$326
4,529
kWh
|
$93
-
kW-mo/yr
|
|
03 | 2.7221: Lower temperature during the winter season and vice-versa | $105 | - |
$94
1,309
kWh
|
$11
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $29,192 | $283,322 |
$21,996
305,502
kWh
|
$7,196
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs