Assessment Year 2024
Principal Product Dock Levelers and Trailer Restraints
NAICS 333924: Industrial Truck, Tractor, Trailer, and Stacker Machinery Manufacturing
SIC 3537: Industrial Trucks, Tractors, Trailers, and Stackers
Sales Range $100
M
to 500
M
# of Employees 339
Plant Area 425,000
ft2
Annual Production 43,000
units
Production Hrs. Annual 6,100
hrs
Location (State) Mississippi

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $255,927 4,450,200
kWh
Electricity Demand $45,497 10,404
kW-mo/yr
Electricity Fees $198,059 -
Natural Gas $61,742 10,803
MMBtu
LPG $7,986 279
MMBtu
TOTAL YEARLY COSTS $569,212
RECOMMENDED SAVINGS* $100,915 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings LPG Savings
01 2.1321: Replace fossil fuel equipment with electrical equipment $6,979 $25,000 $(-1,007.4)
(-17,520)
kWh
- $7,986
-
MMBtu
02 2.4239: Eliminate or reduce compressed air usage $20,601 $8,975 $20,601
358,276
kWh
- -
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $4,008 $1,523 $4,008
70,136
kWh
- -
04 2.4231: Reduce the pressure of compressed air to the minimum required $3,356 - $3,356
57,867
kWh
- -
05 2.7132: Install timers on light switches in little used areas $1,396 $255 $1,396
24,506
kWh
- -
06 2.9114: Use solar heat to make electricty $64,575 $710,500 $57,284
996,079
kWh
$7,291
-
kW-mo/yr
-
TOTAL RECOMMENDED $100,915 $746,252 $85,637
1,489,344
kWh
$7,291
-
kW-mo/yr
$7,986
-
MMBtu
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings LPG Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs