| Assessment Year | 2023 |
|---|---|
| Principal Product | Aluminum Cans |
| NAICS | 332431: Metal Can Manufacturing |
| SIC | 3411: Metal Cans |
| Sales Range | $100 M to 500M |
| # of Employees | 203 |
| Plant Area |
279,000
ft2
|
| Annual Production | 3,500,000
units
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Mississippi |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $2,260,613 | 48,400,168 |
kWh
|
$0.047 | |
| Electricity Demand | $189,348 | 74,254 |
kW-mo/yr
|
$2.55 | |
| Electricity Fees | $140,778 | - |
|
- | |
| Natural Gas | $707,770 | 72,558 |
MMBtu
|
$9.75 | |
| Waste Disposal Costs | |||||
| Water Usage | $519,202 | 82,063 |
Tgal
|
$6.33 | |
| TOTAL YEARLY COSTS | $3,817,710 | ||||
| RECOMMENDED SAVINGS* | $432,283 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7135: Install occupancy sensors | $616 | $1,823 |
$616
12,314
kWh
|
- | |
| 02 | 2.9114: Use solar heat to make electricty | $409,558 | $6,118,420 |
$409,558
8,769,985
kWh
|
- | |
| 03 | 2.3212: Optimize plant power factor | $22,109 | $49,509 | - | $22,109 | |
| TOTAL RECOMMENDED | $432,283 | $6,169,752 |
$410,174
8,782,299
kWh
|
$22,109 | ||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs