ITAC Assessment: MS0420
ITAC logo
ITAC Assessment: MS0420
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2023
Principal Product Aluminum Cans
NAICS 332431: Metal Can Manufacturing
SIC 3411: Metal Cans
Sales Range $100
M
to 500
M
# of Employees 203
Plant Area 279,000
ft2
Annual Production 3,500,000
units
Production Hrs. Annual 8,760
hrs
Location (State) Mississippi

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $2,260,613 48,400,168
kWh
Electricity Demand $189,348 74,254
kW-mo/yr
Electricity Fees $140,778 -
Natural Gas $707,770 72,558
MMBtu
Waste Disposal Costs
Water Usage $519,202 82,063
Tgal
TOTAL YEARLY COSTS $3,817,710
RECOMMENDED SAVINGS* $432,283 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Fees Savings
01 2.7135: Install occupancy sensors $616 $1,823 $616
12,314
kWh
-
02 2.9114: Use solar heat to make electricty $409,558 $6,118,420 $409,558
8,769,985
kWh
-
03 2.3212: Optimize plant power factor $22,109 $49,509 - $22,109
TOTAL RECOMMENDED $432,283 $6,169,752 $410,174
8,782,299
kWh
$22,109
TOTAL IMPLEMENTED - - - -
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs