| Assessment Year | 2023 |
|---|---|
| Principal Product | Wastewater |
| NAICS | 221320: Sewage Treatment Facilities |
| SIC | 4952: Sewerage Systems |
| Sales Range | $10 M to 50M |
| # of Employees | 13 |
| Plant Area |
800,000
ft2
|
| Annual Production | 29,900,000
Tgal
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Mississippi |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $185,391 | 2,566,396 |
kWh
|
$0.072 | |
| Electricity Demand | $48,932 | 4,688 |
kW-mo/yr
|
$10.44 | |
| Electricity Fees | $525 | - |
|
- | |
| Waste Disposal Costs | |||||
| Water Usage | $546 | 202 |
Tgal
|
$2.70 | |
| TOTAL YEARLY COSTS | $235,393 | ||||
| RECOMMENDED SAVINGS* | $36,246 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.2515: Use optimum thickness insulation | $276 | $1,511 |
$276
3,827
kWh
|
|
| 02 | 2.9114: Use solar heat to make electricty | $35,678 | $304,500 |
$35,678
495,526
kWh
|
|
| 03 | 2.4133: Use most efficient type of electric motors | $293 | $1,944 |
$293
4,063
kWh
|
|
| TOTAL RECOMMENDED | $36,246 | $307,955 |
$36,246
503,415
kWh
|
||
| TOTAL IMPLEMENTED | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs