ITAC Assessment: MS0397
ITAC logo
ITAC Assessment: MS0397
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2022
Principal Product Motorhomes
NAICS 321991: Manufactured Home (Mobile Home) Manufacturing
SIC 2451: Mobile Homes
Sales Range less than $500
k
# of Employees 255
Plant Area 108,000
ft2
Annual Production 3,185
units
Production Hrs. Annual 2,750
hrs
Location (State) Mississippi

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $247,498 3,235,500
kWh
Electricity Demand $206,112 15,181
kW-mo/yr
Electricity Fees $2,118 -
Natural Gas $217,259 28,353
MMBtu
TOTAL YEARLY COSTS $672,987
RECOMMENDED SAVINGS* $5,276 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.1321: Replace fossil fuel equipment with electrical equipment $851 $7,078 $(-572.6)
(-7,485)
kWh
$1,424
-
MMBtu
02 2.1121: Use insulation in furnaces to facilitate heating / cooling $2,868 $2,607 - $2,868
-
MMBtu
03 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $1,556 $1,796 $1,556
20,389
kWh
-
TOTAL RECOMMENDED $5,276 $11,481 $983
12,904
kWh
$4,292
-
MMBtu
TOTAL IMPLEMENTED - - - -
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs