Assessment Year | 2022 |
---|---|
Principal Product | Motorhomes |
NAICS | 321991: Manufactured Home (Mobile Home) Manufacturing |
SIC | 2451: Mobile Homes |
Sales Range | less than $500 k |
# of Employees | 255 |
Plant Area |
108,000
ft2
|
Annual Production | 3,185
units
|
Production Hrs. Annual | 2,750
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $247,498 | 3,235,500 |
kWh
|
$0.076 |
Electricity Demand | $206,112 | 15,181 |
kW-mo/yr
|
$13.58 |
Electricity Fees | $2,118 | - |
|
- |
Natural Gas | $217,259 | 28,353 |
MMBtu
|
$7.66 |
TOTAL YEARLY COSTS | $672,987 | |||
RECOMMENDED SAVINGS* | $5,276 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.1321: Replace fossil fuel equipment with electrical equipment | $851 | $7,078 |
$(-572.6)
(-7,485)
kWh
|
$1,424
-
MMBtu
|
|
02 | 2.1121: Use insulation in furnaces to facilitate heating / cooling | $2,868 | $2,607 | - |
$2,868
-
MMBtu
|
|
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,556 | $1,796 |
$1,556
20,389
kWh
|
- | |
TOTAL RECOMMENDED | $5,276 | $11,481 |
$983
12,904
kWh
|
$4,292
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs