Assessment Year | 2012 |
---|---|
Principal Product | Automotive Metal Parts |
NAICS | 336370: Motor Vehicle Metal Stamping |
SIC | 3465: Automotive Stampings |
Sales Range | $10 M to 50M |
# of Employees | 106 |
Plant Area |
392,000
ft2
|
Annual Production | 1
units
|
Production Hrs. Annual | 4,900
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $618,150 | 11,048,995 |
kWh
|
$0.056 |
Electricity Demand | $127,940 | 23,914 |
kW-mo/yr
|
$5.35 |
Electricity Fees | $72,545 | - |
|
- |
Natural Gas | $49,199 | 5,688 |
MMBtu
|
$8.65 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $63,788 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $23,618 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $21,667 | $253,328 |
$19,199
336,839
kWh
|
$2,468
-
kW-mo/yr
|
- | - | |
02 | 2.7241: Install outside air damper / economizer on hvac unit | $32,459 | $4,830 |
$29,048
511,505
kWh
|
- | $3,411 | - | |
03 | 2.2437: Recover waste heat from equipment | $6,854 | $7,104 | - | - | - |
$6,854
-
MMBtu
|
|
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,951 | $386 |
$1,720
30,776
kWh
|
- | $231 | - | |
05 | 2.7135: Install occupancy sensors | $857 | $97 |
$760
13,376
kWh
|
- | $97 | - | |
TOTAL RECOMMENDED | $63,788 | $265,745 |
$50,727
892,496
kWh
|
$2,468
-
kW-mo/yr
|
$3,739 |
$6,854
-
MMBtu
|
||
TOTAL IMPLEMENTED | $23,618 | $253,714 |
$20,919
367,615
kWh
|
$2,468
-
kW-mo/yr
|
$231 | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs