Assessment Year | 2011 |
---|---|
Principal Product | Wire and Cable |
NAICS | 331420: Copper Rolling, Drawing, Extruding, and Alloying |
SIC | 3357: Drawing and Insulating of Nonferrous Wire |
Sales Range | $100 M to 500M |
# of Employees | 230 |
Plant Area |
500,000
ft2
|
Annual Production | 84,000,000
lb
|
Production Hrs. Annual | 8,568
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $948,116 | 20,023,259 |
kWh
|
$0.047 |
Electricity Demand | $362,733 | 37,865 |
kW-mo/yr
|
$9.58 |
Electricity Fees | $6,863 | - |
|
- |
Natural Gas | $260,907 | 49,971 |
MMBtu
|
$5.22 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $139,625 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $86,714 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,069 | $317 |
$3,022
64,625
kWh
|
- | $47 | - | |
02 | 2.2136: Install / repair insulation on steam lines | $43,721 | $10,838 | - | - | - |
$43,721
-
MMBtu
|
|
03 | 2.2136: Install / repair insulation on steam lines | $9,190 | $5,056 | - | - | - |
$9,190
-
MMBtu
|
|
04 | 2.7135: Install occupancy sensors | $3,053 | $3,424 |
$3,007
63,515
kWh
|
- | $46 | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $76,407 | $144,900 |
$58,657
1,238,804
kWh
|
$16,620
-
kW-mo/yr
|
$1,130 | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,185 | $26,542 |
$3,213
67,849
kWh
|
$910
-
kW-mo/yr
|
$62 | - | |
TOTAL RECOMMENDED | $139,625 | $191,077 |
$67,899
1,434,793
kWh
|
$17,530
-
kW-mo/yr
|
$1,285 |
$52,911
-
MMBtu
|
||
TOTAL IMPLEMENTED | $86,714 | $175,183 |
$67,899
1,434,793
kWh
|
$17,530
-
kW-mo/yr
|
$1,285 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs