| Assessment Year | 1994 |
|---|---|
| Principal Product | lawn & garden equipment |
| NAICS |
n/a
|
| SIC | 3524: Lawn and Garden Tractors and Home Lawn and Garden Equipment |
| Sales Range | $100 M to 500M |
| # of Employees | 750 |
| Plant Area |
1,740,000
ft2
|
| Annual Production | 1,000,000
pieces
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Arizona |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $358,455 | 5,303,634 |
kWh
|
$0.068 |
| Natural Gas | $20,102 | 3,509 |
MMBtu
|
$5.73 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $68,309 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $36,191 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $27,163 | $82,461 |
$27,163
401,817
kWh
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $356 | - |
$356
4,103
kWh
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $553 | $540 |
$553
8,206
kWh
|
|
| 04 | 2.7135: Install occupancy sensors | $741 | $970 |
$741
10,844
kWh
|
|
| 05 | 2.2511: Insulate bare equipment | $3,939 | $5,720 |
$3,939
58,324
kWh
|
|
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $327 | $120 |
$327
4,982
kWh
|
|
| 07 | 2.4314: Use synthetic lubricant | $2,924 | $3,915 |
$2,924
21,981
kWh
|
|
| 08 | 2.4133: Use most efficient type of electric motors | $6,997 | $6,080 |
$6,997
103,458
kWh
|
|
| 09 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,151 | - |
$1,151
16,999
kWh
|
|
| 10 | 2.8114: Change rate schedules or other changes in utility service | $24,158 | $50,250 |
$24,158
-
kWh
|
|
| TOTAL RECOMMENDED | $68,309 | $150,056 |
$68,309
630,714
kWh
|
||
| TOTAL IMPLEMENTED | $36,191 | $89,201 |
$36,191
535,462
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs