Assessment Year | 2010 |
---|---|
Principal Product | Cable Products |
NAICS | 335929: Other Communication and Energy Wire Manufacturing |
SIC | 3357: Drawing and Insulating of Nonferrous Wire |
Sales Range | $100 M to 500M |
# of Employees | 63 |
Plant Area |
218,785
ft2
|
Annual Production | 6,000
thousand feet
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $108,310 | 2,304,426 |
kWh
|
$0.047 |
Electricity Demand | $23,663 | 8,764 |
kW-mo/yr
|
$2.70 |
Electricity Fees | $22,273 | - |
|
- |
Natural Gas | $34,726 | 4,021 |
MMBtu
|
$8.64 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $50,398 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $31,176 | $38,740 |
$24,731
511,971
kWh
|
$3,611
-
kW-mo/yr
|
$2,834 | |
02 | 2.4131: Size electric motors for peak operating efficiency | $10,766 | $6,978 |
$8,874
183,717
kWh
|
$993
-
kW-mo/yr
|
$899 | |
03 | 2.4226: Use / purchase optimum sized compressor | $7,079 | $32,037 |
$5,522
114,306
kWh
|
$891
-
kW-mo/yr
|
$666 | |
04 | 2.7232: Replace existing hvac unit with high efficiency model | $1,377 | $59,145 |
$1,302
26,952
kWh
|
- | $75 | |
TOTAL RECOMMENDED | $50,398 | $136,900 |
$40,429
836,946
kWh
|
$5,495
-
kW-mo/yr
|
$4,474 | ||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs